Engineering R&D ] Automation ] Vision Inspection ] Test Fixtures ] Large Machinery ] Retrofits ] Adhesives ] [ Nuclear Power ] Whats Happening @ IAS Corp? ] About / History ] Customers ] Consumer Products ]

 

 

 

 

 

Nuclear Power

 
 

---------------------------------------------------------------------------------------------------------------------------------------

 
 

IAS Corp has provided our services to Surry Nuclear Power Station for over 12 Years.  Our equipment has helped reduce testing time for back-up power generators, make motor operated valve testing easier, ensure equipment is up to specifications for use, and more..

 
 

Some past projects below - Call or email us today for more information

 
     
 
Induspec78 Data Acquisition System  

 

 

 

   Surry Nuclear Power Station in Surry VA. has 3 emergency diesel generators to ensure they can supply power at all times.  The Nuclear Regulatory Commission has mandated that these generators must be tested periodically to ensure that they are within specifications and will perform as designed if needed.  Prior to the Induspec78 this was done by connecting meters, oscilloscopes, and other various pieces of test equipment to individual components in the control cabinet.

   The Induspec78 is the ultimate in diesel testing.  Connect it to the components in the control cabinet and run the test routine.  The system collects 1000 samples per second and records to the hard drive.  The data can be imported into a template that depicts a perfect run.  Any deviation from a perfect test is quickly detected and the problem can be quickly corrected. Induspec Data Acquisition Systems were manufactured exclusively for Surry Nuclear Power Station.  We can provide a custom system for your needs too!

   
         

   ------------------------------------------------------------------------------------------------------------------------------------

         
CaliClamp3  

 

   Our CaliClamp systems verify strain gauge clamps used in Motor Operated Valve testing are within specification.  CaliClamp3 is our latest revision. Testing of the strain gauge clamps is normally performed between outages by cycling the clamp 30 times and recording the results to a database. The results are inserted into a formula provided by the clamp manufacturer to determine if it is still within tolerance.  After testing, a report is generated for each clamp.  The system can be provided as turn key or as an update to existing stem test stand.  This system is the best way to ensure a bad clamp is never used.    
         

------------------------------------------------------------------------------------------------------------------------------------

         
Industrial Light Link  

 

   The Industrial Light Link is a digital communications system that can transmit and receive voice between multiple headsets over a single common wire and earth ground. The input/output line is isolated from the equipment. The headsets feature noise cancellation microphones and soft ear pads that eliminated background noise and are comfortable to be worn all day.  They can be used in voice activation or Push to talk mode. An unlimited number of sets can be connected to the same line and used to talk over different channels. These are used at Surry power station to speed up test times and reduce fatigue for over 8 years now.    
         

------------------------------------------------------------------------------------------------------------------------------------

         
 

 

Click here to visit the Surry Nuclear Power Station Website

 

     
 

We maintain a fully equipped electronic repair lab qualified to repair the following items:

 
 

Machine Controls - Operator Panels - Touch Screens - Hand Wheels - AC & DC Drives - Electronic Modules - PLC's - Monitors - and more...

 
     
 

 
     
     
 

Contact

 
     
     
 

2008 IAS Corp